19
Zone connections
Connecting the panel with radars (infrared movement detectors, PIR) or other devices which require
power. For the connection, 4 cables are required (6 if the TAMPER is connected). The 2 cables are
connected to the (12V) and (-) of the panel and provide power to the respective terminals of all the
detectors. The other 2 cables connect in series the contacts RELAY (NC) of all the detectors of the
zone and the resistors found on the terminals of the panel. The diagram above provides examples for
connecting 1 or 2 detectors on the zones.
For the connection of mag-
netic contacts or other de-
vices that do not require
power only 2 cables are re-
quired.
The diagram to the left
shows the connections with
one or two magnetic con-
tacts on the zones.