D-17
6.
Disassembly
of
CA8961
(Frame)
and
the
exposure
meter
1)
Remove
HK1.7
-
405SN
on
CA8981
(Holder).
Then
comes
off
CA8981.
2)
Remove
CA9011
(Holder).
Then
comes
off
CA9010
(Cam).
3)
Remove
HK1.4
-
101SN
on
CA8995
(Base).
4)
Remove
two
CA9142
(Screw).
Then
will
come
off
in
a
unit:
CA8977
(Plate)
CA8996
(Gear)
CA8998
(Shaft)
CA8999
(Spring)
5)
Remove
CA9021
(Spring)
from
CA8995
(Base)
#951
exposure
meter
mechanism
is
removed
together
with
CA8982.
6)
Remove
two
PUK2
x
3SO
on
CA8995.
Then
comes
off
CA8995.