35 AC Servomotors/Servo Drives 1S-series Instruction Manual
Installation Environment
• Attach the included warning label inside the control panel.
Servo Drive Rating
200-VAC Input Model: R88D-1SANH-ECT
Compatibility Conditions of UL/CSA Standards
Item Specifications
Maximum surrounding Air Temperature 55°C
Storage environment rating (For Canada) -20 to 65°C
Overvoltage category III
Pollution Degree 2
Location At a maximum altitude of 1,000 m
Protection class I
Input power supply
AC power supply
When the DC power input is used, the Servo
Drive does not conform to UL/CSA standards.
Item Unit
Model (R88D-1SAN)
02H-ECT 04H-ECT 08H-ECT
Rated voltage VAC
200 to 240
Single-phase/3-phase
Power supply frequency Hz 50/60
Rated input
current
Single-phase Arms 2.7 4.6 7.3
3-phase Arms 1.5 2.7 4.0
Rated output current (FLA) Arms 1.5 2.5 4.6
Short-circuit current rating (SCCR) --- 240 V 5,000 Arms
Item Unit
Model (R88D-1SAN)
10H-ECT 15H-ECT 20H-ECT 30H-ECT
Rated voltage VAC
200 to 240
3-phase
Single-
phase/3-
phase
3-phase
Power supply frequency Hz 50/60
Rated input
current
Single-phase Arms --- 15.7 --- ---
3-phase Arms 5.8 9.0 13.0 15.9
Rated output current (FLA) Arms 7.7 9.7 16.2 22.3
Short-circuit current rating
(SCCR)
--- 240 V 5,000 Arms