Protective and Diagnostic Functions
33
Fault display Probable cause and remedyWarning name and Meaning
%p1
(flashing)
Operation error (OPj)
(Parameter setting error)
• The values in n36 through n39 for multi-function inputs 1 through 4 have been duplicated.
→ Check and correct the values.
%p2
(flashing)
• The V/f pattern settings do not satisfy the following condition.
n14 x n12 t n11x n09
→ Check and correct the set value.
%p3
(flashing)
• The rated motor current set in n32 exceeds
150% of the rated output current of the Inverter.
→ Check and correct the value.
%p4
(flashing)
• The frequency reference upper limit set in n30 and the frequency reference lower limit set in n31 do
not satisfy the following condition.
n30 y n31
→ Check and correct the set values.
%p5
(flashing)
• The jump frequencies set n49, n50 do not satisfy the following condition.
n49 y n50
→ Check and correct the set values.