342
PLC Comparison Charts Appendix A
Table Data
Processing
Instructions
SET STACK SSET Yes (Four words
of stack control
information.
Number of
words specified
in binary: 5 to
65535)
Yes (Four words
of stack control
information.
Number of
words specified
in binary: 5 to
65535)
No Yes (Four words
of stack control
information.
Number of
words specified
in BCD: 3 to
9999)
No
PUSH ONTO
STACK:
PUSH Yes Yes No Yes No
FIRST IN FIRST
OUT
FIFO Yes Yes No Yes No
LAST IN FIRST
OUT
LIFO Yes Yes No Yes No
FIND MAXIMUM/
FIND MINIMUM
MAX,
MIN
Yes (Two words
in control data
field. Table
length specified
in binary: 1 to
FFFF)
Yes (Two words
in control data
field. Table
length specified
in binary: 1 to
FFFF)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
DATA SEARCH SRCH Yes (Table
length specified
in binary: 1 to
FFFF. PLC
memory address
output to IR0.
Number of
matches can be
output to DR0)
Yes (Table
length specified
in binary: 1 to
FFFF. PLC
memory address
output to IR0.
Number of
matches can be
output to DR0)
Yes (Table
length specified
in BCD: 1 to
6556. PLC
memory address
output to C+1.
Number of
matches cannot
be output to
DR0)
Yes (Table
length specified
in BCD: 1 to
9999. PLC
memory address
output to IR0.
Number of
matches cannot
be output to
DR0)
Yes (Table
length specified
in BCD: 1 to
6556. PLC
memory address
output to C+1.
Number of
matches cannot
be output to
DR0)
FRAME CHECK-
SUM
FCS Yes Yes Yes No Yes
SUM SUM Yes (Same as
C200HX/HG/
HE: Sum possi-
ble for bytes as
well as words.)
Yes (Same as
C200HX/HG/
HE: Sum possi-
ble for bytes as
well as words.)
Yes (Sum possi-
ble for bytes as
well as words.)
Yes (Sum possi-
ble for words
only.)
Yes (Sum possi-
ble for bytes as
well as words.)
SWAP BYTES SWAP Yes (Can be
used for data
communications
and other appli-
cations.)
Yes (Can be
used for data
communications
and other appli-
cations.)
No No No
DIMENSION
RECORD TABLE:
DIMYesYesNoNoNo
SET RECORD
LOCATION
SETR Yes Yes No No No
GET RECORD
LOCATION
GETR Yes Yes No No No
Data Con-
trol Instruc-
tions
SCALING SCL Yes Yes Yes No Yes
SCALING 2 SCL2 Yes Yes No No Yes
SCALING 3 SCL3 Yes Yes No No Yes
PID CONTROL PID Yes (Output can
be switched
between 0% and
50% when PV =
SV. PID and
sampling period
specified in
binary.)
Yes (Output can
be switched
between 0% and
50% when PV =
SV. PID and
sampling period
specified in
binary.)
Yes (PID and
sampling period
specified in
BCD)
Yes (PID and
sampling period
specified in
BCD) (*1)
Yes (PID and
sampling period
specified in
BCD)
PID CONTROL
WITH AUTO-
TUNIG
PIDAT CJ1: No
CJ1-H: Yes
CJ1M: Yes
CS1: No
CS1-H: Yes
No No No
LIMIT CONTROL LMT Yes Yes No Yes (*1) No
DEAD BAND CON-
TROL
BAND Yes Yes No Yes (*1) No
DEAD ZONE CON-
TROL
ZONE Yes Yes No Yes (*1) No
AVERAGE AVG Yes (Number of
scans specified
in binary)
Yes (Number of
scans specified
in binary)
Yes (Number of
scans specified
in BCD)
No Yes (Number of
scans specified
in BCD)
Item Mne-
monic
CJ Series CS Series C200HX/HG/HE CVM1/CV
Series
CQM1H