14. Changing Set Value of Timer
The set value of a timer is changed while CPU is running (in the Monitor mode only).
Move the cursor to the
set value of a timer.
Enter the new set value #100.
Click [OK] to complete.
15. Changing Present Value of Timer
Move the cursor to the
present value of a
timer.
Enter a new present value 5000.
Click [Set] to complete.
The present value of a timer is changed while CPU is running (in the Monitor mode only).