4 Basic Operation
4 - 46
E5@C-T Digital Temperature Controllers User’s Manual (H185)
z Rate of Rise Programming
• If the rate of rise is changed during a segment, both the slope of the present SP and the segment
time for the ramp period will change.
• If the SP is changed during a segment, the segment time for the ramp period will change.
• If the time is changed during a segment, the segment time for the soak period will change.
Set point
Point of
change
Before change
Time
After change
After change
Before change
Segment N
Segment N
Segment N+1
Segment N+1