E8F2 E8F2
18
or
Press Up or Down key to
change set value.
Display Refresh Interval Setting
• The following refresh intervals are selectable.
0.1: The average value i s displayed at 0.1-s intervals.
0.5: The average value i s displayed at 0.5-s intervals.
1.0: The average value i s displayed at 1.0-s intervals.
1. Press the S ET key whil e dsp is displ ayed to displ ay the display refresh interval presently set.
2. Press the Up or Down key to change the set value.
3. Press the S ET key to select the di splayed set value and display dsp again.
4. Press the Up and D own keys simultaneously to displ ay dsp again without selecting the set value.
Note: Set the AVE to the number of measurements for obtaining an average value.
OUT1 OUT2 kPa Torr Psi
OUT1 OUT2 kPa Torr Psi
or
Press Up or Down Key to
change set value.
OUT1 OUT2 kPa Torr Psi
OUT1 OUT2
kPa Torr Psi
Measurement Value Averaging Time Setting
The number of measurements can be set to 1, 8, 32, or 256.
1. Press the S ET key whil e aUe is displ ayed to displ ay the set val ue as the number of measurements for averaging measured values.
2. Press the Up or Down key to change the set value.
3. Press the S ET key to select the di splayed set value and display aUe again.
4. Press the Up and D own keys simultaneously to displ ay aUe again without selecting the set value.
Note: If the DSP item is set to 0.5 and AVE item is set to 32, the E8F2 will measure 32 times, the average value of which will be treated
as one block. The average block value for 0.5 s will be displayed at 0.5-s intervals.