[Output]
Object signals:
No.15 to 19 pin: Use the COMOUT0 terminal when using these signals.
No.49, 51 to 57 pins: Use the COMOUT2 terminal when using these signals.
No.58 to 66 pins: Use the COMOUT3 terminal when using these signals.
Item Specifications
Output voltage 12 to 24 VDC ±10 %
Load current
*1
45 mA max.
ON residual voltage 2 V max.
OFF leakage cur-
rent
0.2 mA max.
*1. The load current must be the specified current value or lower. Exceeding the specified current value may
cause damage to the output circuit.
l
[Output]
Object signals:
No.20 to 23 pins:Use COMOUT1 and COMIN0 when using these signals.
Item Specifications
Output voltage 12 to 24 VDC ±10 %
Load current
*1
45 mA max.
ON residual voltage 2 V max.
OFF leakage cur-
rent
0.2 mA max.
*1. The load current must be the specified current value or lower. Exceeding the specified current value may
cause damage to the output circuit.
l
Connection
Connect the parallel I/O cable with more than the minimum bending radius.