EasyManuals Logo

Omron HBF-702T User Manual

Omron HBF-702T
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
29
When necessary
16. Technical Data
Product Description OMRON Body Composition Monitor
Model HBF-702T
Display*
1
Body Weight:
3.0 to 100.0 kg with an increment of 0.1 kg
100.0 to 135.0 kg with an increment of 0.2 kg
BMI: 2.5 to 90.0 with an increment of 0.1
BMI Classification: – (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
Body Fat Percentage: 5.0 to 50.0% with an increment of 0.1%
Over 10
years old
Segmental Subcutaneous Fat Percentage:
(Whole Body, Trunk, Legs, Arms)
5.0 to 60.0% with an increment of 0.1%
Segmental Skeletal Muscle Percentage:
Whole Body, Arms
Trunk
Legs
5.0 to 60.0% with an increment of 0.1%
5.0 to 50.0% with an increment of 0.1%
5.0 to 70.0% with an increment of 0.1%
Body Fat Percentage, Subcutaneous Fat Percentage,
Skeletal Muscle Percentage Classification:
– (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
Resting Metabolism: 385 to 3999 kcal with an increment of 1 kcal
Body Age: 18 to 80 years old with an increment of 1 year
Over 18
years old
Visceral Fat Level: 0.5 to 30 levels with an increment of 0.5 level
Visceral fat level classification:
0 (Normal) / + (High) / ++ (Very High) 3 levels
Transmission Protocol
Bluetooth
®
low energy technology
Wireless
communication
Frequency range:
Modulation:
Effective radiated power:
2.4 GHz (2400 - 2483.5 MHz)
GFSK
<20 dBm
Setting Items*
2
The following information can be stored for up to 4 users (30 memories per
user).
Measurement unit kg&cm
Birth date January 1st, 1900 to December 31st, 2045
Gender Male / Female
Height 100.0 to 199.5 cm with an increment of 0.5 cm
Weight Accuracy 3.0 kg to 40.0 kg: ± 0.4 kg
40.0 kg to 135.0 kg: ± 1%
Accuracy (S.E.E.*
3
) Body Fat percentage: 3.5%
Skeletal Muscle percentage: 3.5%
Visceral Fat Level: 3 levels
Durable Period 5 years
Power Supply 4 AA alkaline batteries (LR6)
Battery Life Approximately 6 months (When AA alkaline batteries are used in four
measurements, four data transfers and fo
ur persons a day at a room
temperature of 23°C)
Operating Temperature/
Humidity/Air Pressure
+5°C to +40°C, 30% to 85% RH (no-condensing), 860 hPa to 1060 hPa