EasyManua.ls Logo

Omron M2 Basic - User Manual

Omron M2 Basic
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Digital Automatic Blood Pressure Monitor
Model M2 Basic
• Instruction Manual
• Gebrauchsanweisung
EN
DE
IM-HEM-7116-E(V)-03-05/2012
5331307-2C
12E1131
HEM-7116-E(V)_EN_DE.book Page 1 Monday, June 18, 2012 4:21 PM

Other manuals for Omron M2 Basic

Questions and Answers

  • J
    joshua11Jul 29, 2025
    What to do if the Omron M2 Basic displays an error or can't complete measurement after inflation?
    • W
      wolfescottJul 29, 2025
      If your Omron Blood Pressure Monitor displays an error or cannot complete a measurement after the arm cuff inflates, it might be because you moved or talked during the measurement, preventing sufficient inflation. Remain still and avoid talking during the measurement. If 'E2' appears repeatedly, manually inflate the arm cuff until the systolic pressure is 30 to 40 mmHg above your previous readings.
  • J
    Joseph RussoAug 3, 2025
    Why is my Omron M2 Basic Blood Pressure Monitor reading so high/low?
    • K
      kbridgesAug 3, 2025
      An incorrect reading on your Omron Blood Pressure Monitor can occur if the arm cuff is not applied correctly, if you move or talk during the measurement, or if clothing interferes with the arm cuff. Make sure to apply the arm cuff correctly, remain still and do not talk during measurement and remove any clothing interfering with the arm cuff.
  • C
    Courtney ZimmermanAug 7, 2025
    How to fix an Omron M2 Basic Blood Pressure Monitor when the arm cuff doesn't inflate?
    • E
      Eric PhillipsAug 7, 2025
      If your Omron Blood Pressure Monitor's arm cuff doesn't inflate, consider these possibilities: 1. You might have pressed the [START/STOP] button without the arm cuff applied. Press the [START/STOP] button again to turn the monitor off, then after inserting the air plug securely and applying the arm cuff correctly, press the [START/STOP] button again. 2. The air plug might not be fully inserted. Ensure the air plug is securely inserted. 3. The arm cuff may not be applied correctly. Apply the arm cuff correctly, then take another measurement. 4. Air could be leaking from the arm cuff. Replace the arm cuff with a new one.
  • J
    Jonathan LuceroAug 11, 2025
    Why does the arm cuff on my Omron Blood Pressure Monitor deflate too soon?
    • D
      Diane SaundersAug 11, 2025
      If the arm cuff on your Omron Blood Pressure Monitor deflates too soon, it's likely because the arm cuff is loose. Apply the cuff correctly so that it is firmly wrapped around your arm.
  • U
    uturnerAug 16, 2025
    What to do if my Omron Blood Pressure Monitor loses power during measurement?
    • J
      Jordan HernandezAug 16, 2025
      If your Omron Blood Pressure Monitor loses power during measurement, the batteries are likely empty. Replace the batteries with new ones.
  • T
    tdanielAug 20, 2025
    What to do if nothing happens when I press the buttons on my Omron M2 Basic Blood Pressure Monitor?
    • M
      Misty MaldonadoAug 20, 2025
      If nothing happens when you press the buttons on your Omron Blood Pressure Monitor, it could be due to empty or incorrectly inserted batteries. Replace the batteries with new ones, ensuring they are inserted with the correct (+/ -) polarity.
  • C
    Cheryl LloydAug 25, 2025
    Why won't the arm cuff pressure rise on my Omron M2 Basic?
    • K
      Kimberly HamptonAug 26, 2025
      If the arm cuff pressure doesn't rise on your Omron Blood Pressure Monitor, it may be due to the air plug not being securely inserted into the main unit, or air leaking from the arm cuff. Ensure the air plug is connected securely. If the issue persists, replace the arm cuff with a new one.

Summary

Important Safety Information

2. Preparation

Installing;Replacing the Batteries

Step-by-step instructions on how to insert or replace the batteries in the main unit.

3. Using the Unit

How to Sit Correctly When Taking a Measurement

Guidance on proper posture and environment for accurate blood pressure measurement.

Applying the Arm Cuff

Instructions on how to correctly wrap the arm cuff on the upper arm for measurement.

Taking a Reading

Step-by-step guide on initiating and performing a blood pressure measurement.

Instructions for Special Conditions

Procedures for taking measurements under specific conditions, like high systolic pressure.

4. Quick Reference Guide

5. Handling Errors and Problems

Error Messages

Details error displays, their causes, and recommended remedies for troubleshooting.

Troubleshooting

Provides solutions for common problems encountered with the blood pressure monitor.

6. Maintenance and Storage

8. Technical Data

Omron M2 Basic Specifications

General IconGeneral
ModelM2 Basic
CategoryBlood Pressure Monitor
Measurement MethodOscillometric
Cuff Size22-32 cm
Measurement Range Pressure0-299 mmHg
Accuracy Pressure±3 mmHg
Accuracy Pulse±5% of reading
Power Source4 x AA batteries
TechnologyIntelliSense
Measurement Range Pulse40-180 beats/min
WeightApproximately 250g (without batteries)
DisplayLCD
Dimensions103 x 80 x 129 mm