75
Receiver Error Codes Section 17-5
Cascaded Sys-
tem Fault
80 Configuration Error Please contact your local Omron distributor
or the European Repair Center
81 Second segment or mute module error Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
82 Third segment or mute module error Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
83 Fourth segment or mute module error Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
84 Mute module error Check all cable connections to mute mod-
ule. Please contact your local Omron dis-
tributor or the European Repair Center
85 Configuration error Please contact your local Omron distributor
or the European Repair Center
86 Second segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
87 Third segment or mute module firmware not
compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
88 Fourth segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
89 Mute module firmware not compatible with
first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
90 Incorrect segment type in position two,
three or four
Confirm that all segments are of the same
type; either all transmitters or receivers
91 Segment 2 type does not match segment 1
type
Confirm that segment 2 is the same type
(transmitter or receiver) as segment 1
92 Segment 3 type does not match segment 1
type
Confirm that segment 3 is the same type
(transmitter or receiver) as segment 1
93 Segment 4 type does not match segment 1
type
Confirm that segment 4 is the same type
(transmitter or receiver) as segment 1
95 Error in flex segment or muting module dur-
ing operation
Check all flex connections, segments and
muting modules
96 Error in segment 2 during operation Check connections to segment 2. Replace
segment 2 with known good segment 2.
Please contact your local Omron distributor
or the European Repair Center
97 Error in segment 3 during operation Check connections to segment 3. Replace
segment 3 with known good segment 3.
Please contact your local Omron distributor
or the European Repair Center
98 Error in segment 4 during operation Check connections to segment 4. Replace
segment 4 with known good segment 4.
Please contact your local Omron distributor
or the European Repair Center
100 Number of segments in system has been
reduced (changed)
Segment count is less than original configu-
ration. Add required segment(s) or program
system for current configuration
101 Too many flex nodes or muting modules in
the flex bus
Make sure of total of 4 segments with only
one muting module.
Code Group Error Code Description of Error Code Corrective Action Needed