58
Sample Ladder Programs Section 4-5
Connection Close
Processing
Connection
1 close
from
remote
device
M200
CLOSE
instruction
completion
device
D200ZP.CLOSE "U0" K1
M202
CLOSE
instruction
normal
completion
SET
M160
Connection
1 close
timing
PLS
M161
Connection
1 close
from
remote
device
PLS
M2000
CLOSE
instruction
1PLS
PLS
M210
CLOSE
instruction
being
executed
SET
M203
CLOSE
instruction
abnormal
completion
SET
M210
CLOSE
instruction
being
executed
RST
END
M161
CLOSE
instruction
being
executed
M210
CLOSE
instruction
abnormal
completion
device
M201
CLOSE
instruction
abnormal
completion
device
M201
CLOSE
instruction
1PLS
M2000
Connection
1 open
completion
signal
M0
CLOSE
instruction
completion
device
M200
Connection
1 open
completion
signal
M0
Connection
1 close
timing
M160
BUFRCV
instruction
normal
completion
M700
OPEN
instruction
normal
completion
M150