76
DST1 Series Monitoring Section 4-7
Instance ID: 333
Monitor value: 1: ON, 0: OFF Status value: 1: Normal, 0: Error
Instance ID: 342
Monitor value: 1: ON, 0: OFF Status value: 1: Normal, 0: Error
4-7-4 Monitoring the DST1-XD0808SL-1
Note (1) Overall Status
Read Data Format (Read Size: 1 Byte)
Status
Offset
(bytes)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
+0 Safety input
terminal No.
3 status
Safety input
terminal No.
2 status
Safety input
terminal No.
1 status
Safety input
terminal No.
0 status
Safety input
terminal No.
3 monitor
Safety input
terminal No.
2 monitor
Safety input
terminal No.
1 monitor
Safety input
terminal No.
0 monitor
+1 Safety out-
put termi-
nal No. 3
monitor
Safety out-
put termi-
nal No. 2
monitor
Safety out-
put termi-
nal No. 1
monitor
Safety out-
put termi-
nal No. 0
monitor
Safety out-
put termi-
nal No. 3
status
Safety out-
put termi-
nal No. 2
status
Safety out-
put termi-
nal No. 1
status
Safety out-
put termi-
nal No. 0
status
+2 Muting
lamp status
Reserved Test output
terminal No.
3 status
Test output
terminal No.
2 status
Test output
terminal No.
1 status
Test output
terminal No.
0 status
Offset
(bytes)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
+0 Test output
terminal No.
3 status
Test output
terminal No.
2 status
Test output
terminal No.
1 status
Test output
terminal No.
0 status
Safety out-
put termi-
nal No. 3
monitor
Safety out-
put termi-
nal No. 2
monitor
Safety out-
put termi-
nal No. 1
monitor
Safety out-
put termi-
nal No. 0
monitor
Service code Class ID Instance ID Request data
(attribute ID)
Safety input monitor
Safety input status
Safety output monitor
Safety output status
Overall status (See note 1.)
Input value/
status
0E hex 04 hex Refer to the table in
note 4.
03 hex
Safety input error cause
(See note 2.)
Error cause 0E hex 3D hex 01 to 08 hex 6E hex
Safety output error cause
(See note 3.)
Error cause 0E hex 3B hex 01 to 08 hex 6E hex
+0 Status
Bit Meaning
0 Input Power Supply Voltage Monitor Flag
0: I/O power supply ON, ON: I/O power supply OFF
1 Output Power Supply Voltage Monitor Flag
OFF: I/O power supply ON, ON: I/O power supply OFF
2 Network Power Supply Voltage Monitor Error Flag
0: Normal (higher than monitor set value), ON: Error (not higher than
monitor set value)
3 Module Maintenance Flag
OFF: Within range (lower than monitor set value), ON: Out of range
(not lower than monitor set value)
4 Operation Mode Flag
OFF: Other than RUN, ON: RUN