43
Mitsubishi Ethernet Interface Module Settings Section 4-4
4-4 Mitsubishi Ethernet Interface Module Settings
This section describes how to make the settings for the Mitsubishi QJ71E71-
100 Ethernet Interface Module.
Note Refer to the following manuals for more details on subjects such as proce-
dures for making settings.
• QSCPU User’s Manual (Function Explanation, Program Fundamentals)
• Q Corresponding Ether Interface Module User’s Manual (Basic)
4-4-1 PC Parameters
I/O Allocations Set the type of Module mounted on the Base Unit, the I/O signal range, etc.
Make the following I/O allocation settings.
Program Set the program file name and the execution type (execution condition). The
program can be written to the CPU Module according to these settings.
In this example, the settings are made as shown in the following table.
4-4-2 Network Parameters
Make the settings for using the Ethernet Module as a network module. Select
MELSECNET/Ethernet in the Network Parameters Window, and then make
the settings as shown in the following table.
EtherNet Operations Make the common Module settings for using the Ethernet Module.
The settings for Ethernet operations are shown in the following table.
Item Contents Setting
Type Set the type of Module that is mounted. Intelli
Model name Set the model name of the Module that is
mounted.
QJ71E71-100
Points Set the number of points for each slot. 32 (32 points)
Start XY Set the starting I/O number for each slot. 0000
Item Contents Setting
Program name Set the name of the program. MAIN
Execute type Execution type (execution condition) Scan
Item Contents Setting
Network type Select the mounted Module. Ethernet
Starting I/O No. Set the starting address for the Module. 0000
Network No. Set the network number for the Module. 1
Group No. Set the group number for the Module. 1
Station No. Select the station number for the Module. 1
Mode Select the operating mode for the Module. Online
Item Contents Setting
Communication data
code setting
Select the communications data code. Binary code com-
munication
Initial Timing Make the OPEN setting. Do not wait for
OPEN
IP
address
setting
Input format Select the input format for the IP address. Decimal
IP address Set the local IP address. 192.168.250.18