EasyManua.ls Logo

Omron NS10-TV Series

Omron NS10-TV Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Cat. No. V098-E1-05
Programmable Terminals
Host Connection Manual:
Host Link
NS15-TX_, NS12-TS_,
NS10-TV_, NS8-TV_,
NS5-SQ_, NS5-TQ_, NS5-MQ_
OPERATION MANUAL

Other manuals for Omron NS10-TV Series

Questions and Answers:

Omron NS10-TV Series Specifications

General IconGeneral
Display TypeTFT LCD
Touch TypeResistive
Backlight Life50, 000 hours
USB PortUSB 2.0
Ethernet10/100 Mbps
Serial PortRS-232C
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s², 3 times each direction
Power Supply24 VDC
Protection RatingIP65 (front panel)
Vibration Resistance10 to 57 Hz: Amplitude 0.075 mm, 57 to 150 Hz: 9.8 m/s2

Summary

Introduction

1-1 Overview

1-2 Connection Configuration

1-2-1 NS-V1 V2 Configuration Required for Connection

Specifies the system configuration requirements for NS-V1/V2 models to connect via Host Link.

1-2-2 Applicable PLCs

Lists OMRON PLCs compatible for connection as hosts using Host Link communications.

1-3 Connecting to the Host

1-3-1 Connecting to an RS-232 C Port at the Host

Details connecting NS-V1/V2 PTs to hosts via RS-232C ports, including compatible units and settings.

1-3-2 Connecting to an RS-422 A485 Port at the Host

Explains connecting NS-V1/V2 PTs to hosts via RS-422A/485 ports, including compatible units.

1-4 Settings for Host Link

1-4-1 Designing the Screen Data

Guides on creating screen data using CX-Designer for Host Link communication setup.

1-4-2 Transferring Screen Data

Describes the procedure for transferring screen data from CX-Designer to the NS-V1/V2 PT.

1-4-3 Setting the Communications Method for Serial Port A or B

Details setting the communications method and baud rate for serial ports on the NS-V1/V2 PT.

1-5 PLC Areas That Can Be Used for Communications

OMRON C-series PLCs

Details the PLC memory areas usable for Host Link communications in OMRON C-series PLCs.

CVM1 CV-series PLCs

Specifies the PLC memory areas usable for Host Link communications in CVM1/CV-series PLCs.

1-6 Restrictions

Applicable Project Versions

Specifies the required CX-Designer project versions for successful Host Link communication.

Applicable Serial Ports

Identifies which serial ports (A or B) on NS-V1/V2 PTs are supported for Host Link.

Applicable NS Models

Lists the NS-series PT models that are compatible with Host Link communications.

Related product manuals