15
04 Commissioning
04.3 Function groups of the parameters
The parameters are divided into individual function groups. The term function applies to both monitoring
modes and parameters. These are all accessible through function codes that are primary 4-character codes. The
various functions are separated into related groups identifiable by the left-most character, as the table shows.
Function group
Type (category) of function
Mode to access
d
Monitoring functions
Monitor
F
Main profile parameters
Program
A
Standard functions
Program
b
Fine tuning functions
Program
C
Intelligent terminal functions
Program
H
Motor constant related functions
Program
P
Pulse train input, torque, Drive
Programming, and
communication
related functions
Program
U
User selected parameters
Program
E
Error codes
-
04.4 Keypad navigation map
The programming of the MX2 can be done via the keypad. Only the following keys on the front keypad are
required for programming:
CYCLE key
SET key
Up key
Down key
The following figure explains the procedure for navigating through the function groups and their parameters,
as well as setting parameters.