3-7
Parameter
No. (Reg-
ister No.
(Hex))
MemoChanges
during
opera-
tion
Default
setting
Setting
range
DescriptionName
n30
(011E)
Fre-
quency
refer-
ence
upper
limit
Used to set the upper and lower fre-
quency reference limits in percent-
age based on the maximum frequen-
cy as 100%.
Note If n31 is set to a value less
than the minimum out
quency (n14), the Inverter will
have no output when a fre-
quency reference less than
the minimum output frequency
input is input.
0 to 110 0 No
n32
(0120)
Rated
motor
current
Used to set the rated motor current
for motor overload detection (OL1)
based on the rated motor current.
Note Motor overload detection
(OL1) is disabled by setting
the parameter to 0.0.
Note The rated motor current is
default to the standard rated
current of the maximum appli-
cable motor.
0.0 to
120% of
rated out-
put current
of the In-
verter.
Varies with
the capac-
ity.
No
n33
(0121)
Motor
protec-
tion
charac-
teristics
Used to set the motor overload
detection (OL1) for the electronic
thermal characteristics of the motor.
0: Protection characteristics for gen-
eral-purpose induction motors
1: Protection characteristics for in-
verter-dedicated motors
2: No protection
Note If a single Inverter is con-
nected to more than one mo-
tor, set the parameter to 2 for
no protection. The parameter
is also disabled by setting n32
for rated motor to 0.0.
0 to 2 0 No
List of Parameters Chapter 3