TX-NR929/ DTR-60.5/ DHC-60.5
OPERATION CHECK-6
3.INITIAL SETTING FOR SHIPPING
a. Initialization of memories.
Press ON/STANDBY button while pressing down CBL/SAT button when the unit is POWER ON, then the FLT displays
"CLEAR", and turn to STAND-BY. Remove power cord from power line.
b. (Please pull out the AC cord at the standby mode.)
4.TEST MODE
4-1
TEST MODE FOR FL DISPLAY
a. Push ON/STANDBY key while pushing down TV/CD button button to display "TEST-".
b. Then push DIMMER (or RT/PTY/TP) button and get the FL test mode.
c. In the FL test mode, TONE - button is FL TEST UP and TONE + button is FL TEST DOWN.
d. REC OUT and ZONE2 button's originally operation can't work when it is in FL test mode.
e. The contents of the step are as follows.
1. Lit all segment
2. Lit upper 'EDCBA987654321', lower '23456789ABCDEF'.
3. Lit a even number segment
4. Lit an odd number segment
5. The Destination is displayed.
Please see the below for detail.
To close the FL test, push ON/STANDBY button.
Display of Destination on TEST MODE.
N R 9 2 9 D 2 0 0 0
MODEL Name Destination A B C D
TX-NR929
:
NR929 Dx: USA A: Value of AD port of BAND
DTR-60.5
:
DTR605 xx: OTHER B: Value of AD port of INIT1
DHC-60.5: DHC605 JJ
:
JAPAN C: Value of AD port of INIT2
D: Value of AD port of INIT3
MODEL Name NR929 DTR605
Destination Dx xx JJ Dx xx JJ
MA
MR
ABCD
2400
8400 4400 2460 8460 4460
MODEL Name DHC605
Destination
ABCD 2480
NOTE :
If VOL value is not 30 (-52dB) (initial setting), test mode cannot be set.
Dx
MA
MB
MP
MR