Installation
NETWORK
REQUIREMENTS
An
Ethernet
connection
with
DHCP
must
be
used
to
connect
the
ACU
to
the
Local
Area
Network
(LAN).
You
also
need
to
configure
firewall
settings
to
communicate
with
the
Openpath
system.
Openpath
uses
the
following
outbound
ports:
TCP
port
443
TCP
port
80
UDP
port
123
Note:
If
using
an
external
DNS
server,
outbound
UDP
port
53
must
also
be
open.
To
support
Wi-Fi
unlocking
from
the
mobile
app,
the
ACU
s
inbound
TCP
port
443
must
be
available
from
within
the
LAN.
Inbound
port
forwarding
on
the
router,
firewall,
or
NAT
device
is
not
required.
SELECTING
A
BACKUP
BATTERY
While
not
required,
Openpath
recommends
having
a
backup
battery
in
case
of
power
outages.
The
size
of
battery
depends
on
your
setup
and
how
long
you
want
to
power
the
system.
Table
1:
Power
requirements
for
legacy
Smart
Hubs
(12V)
Controller
board
1A
Smart
Reader
0.25A
Locking
hardware
(while
engaged)
0.25A
0.5A
Assuming
a
12V
power
supply,
a
Smart
Hub
configured
with
four
Openpath
Readers
and
locking
hardware
uses
4
Amps.
To
keep
the
system
running
for
3
hours
with
all
entries
engaged,
you
need
4A
x
3
hours
=
12AH,
so
a
12V
12AH
sealed
lead
acid
(SLA)
or
gel
cell
battery.
Version 1.8
© Openpath 2020
Page 4