To Previous Page IconTo Previous Page
Loading...
reader
has
been
identified
via
the
Control
Center
reader
is
possibly
not
receiving
enough
voltage
or
current,
potentially
due
to
a
break
in
wiring
try
connecting
the
reader
directly
to
the
ACU,
bypassing
any
wire
runs
check
that
+12V
IN
(orange)
hasn
t
been
swapped
with
+B
(blue)
or
-A
(violet)
LEGACY
WIRING
Sometimes
legacy
wiring
(unshielded
and
straight
through,
rather
than
shielded
twisted
pair,
often
22-6)
results
in
slower
connections
and
dropped
packets
between
the
Openpath
Reader
and
ACU.
To
remedy
this,
you
can
switch
GND
and
VIN
with
+B
and
-A
connections
on
the
ACU
and
readers
to
ensure
the
data
pair
(+B
and
-A)
are
using
the
alternate
pair
of
legacy
wires.
RESETTING
THE
ACU
SOFT RESET
To
soft
reset
the
ACU,
disconnect
power
from
the
ACU,
wait
10
seconds,
then
reconnect
the
power.
HARD RESET
WARNING:
Only
hard
reset
the
ACU
if
absolutely
necessary
and
if
instructed
by
Openpath.
This
will
clear
all
of
the
data
off
of
the
ACU
and
will
require
reprovisioning,
which
requires
having
a
computer
on
the
same
network
as
the
ACU.
To
hard
reset
the
ACU:
1. Disconnect
power
from
the
ACU
2. Hold
down
the
ADMIN
BUTTON
for
15
seconds
Version 1.8