10.SPECIFICATIONS
MODEL
VX-402
~_VX-402REC
Detection
Method
Passive
Infrared
Coverage
12m(40ft)90°
wide
Detection
Zones
14z0nes
Mounting
Height
0.8-1.2m(2.7-4ft)
Sensitivity
2.0°C(3.6°F)
at
0.6m/s
Detectable
Speed
0.3-1.5m/s(1-5ft/s)
Power
Input
9.5-18VDC
Current
Draw
NC
Normal
25mA
Max
28mA
__Normal
25mA
Max
180mA
Normal
10mA
Max
35mA
“Normal
12mA
Max
200mA
Alarm
Period
2+1sec
Alarm
Output
Selectable
N.C./N.O.;
28VDC
0.2A
Max
Tamper
Switch
N.C.
Opens
when
cover
removed
Pulse
Count
20=5sec
2
or
4
Warm-up
Period
Approx
30sec(LED
blinks)
LED
Indicator
Recording
condition
Weatherproof
IP54
Operating
Temperature
—20
-
+50°C(-4
-
+122°F)
Environment
Humidity
95%
Max
RF
Interference
No
Alarm
30V/m
Mounting
Wall.
Pole,
Conduit
and
Electric
box
Weight
§50g(19.40z)
Accessories
Pole
mount
kit,
Screw
Kit,
Area
Masking
Plate
Note:
Specifications
and
design
are
subject
to
change
without
prior
notice,
|
11.DIMENSIONS
Loi
A
NOTE
This
unit
is
designed
to
detect
movement
of
an
intruder
and
activate
an
alarm
control
panel.
Being
only
a
part
of
a
complete
system,
we
cannot
accept
responsibility
for
any
damages
or
other
consequences
resulting
from
an
intrusion.
This
Product
conforms
to
the
EMC
Directive.89/
336
EEC.
5
ORPTEX
OPTEX
CO.,
LTD.
‘iSO
9001
Certified
by
LROA)
4-7-5
Nionohama
Otsu,
520-0801 Japan
TEL
(077)524-6047
FAX
(0773522-9022
OPTEX
INCORPORATED
1845W.
205th
Street
Torrance,
CA
90501-1510
U.S.A
TEL
(310)833-1500
FAX
(310)533-5910
OPTEX
(EUROPE)
LTD.
(iso
9002
Certitiea
by
NOA)
Clivemont
Road.
Cordwallis
Park,
Maidenhead,
Berkshire,
SL6
7BU
U.K.
TEL
(01628)631000
FAX
(91628)636311
-16-