7.4.2. Skew Angle and Dead Zone
Scanning performance is guaranteed when skew angle: β ≤ ±70° (Excluding dead
zone)
Dead zone: β = ±20° (There are some areas in which decoding fails due to
specular reflection)
Β1 = Β2 = 0°
Figure 5: Skew angle and dead zone
7.4.3. Tilt Angle
Scanning performance is guaranteed when γ ≤ ±25°
γ
γ
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Angles:
Pitch angle: Skew angle: β = +0°, Tilt angle: γ = 0°
Tilt angle: Pitch angle: α = 0°, Skew angle: β = +0°
Skew angle, Dead zone: Pitch angle: α = 0°, Tilt angle: γ = 0°
Curvature: R = ∞