MDI-4000 Series Serial Interface Manual
Indicator duration: 60 ms
Indicator duration: 100 ms
Indicator duration: 200 ms
Indicator duration: 400 ms
Indicator duration: 800 ms
9.2.2 Inverted Good Read LED
In Good Read LED inverted mode, the GR_LEDn signal is inverted.
Inverted Good Read LED Commands
Good Read LED normal mode
Good Read LED inverted mode
9.3 Good Read Aiming
When a barcode is successfully read, the green good read aiming light turns on, briefly. You can
configure the frequency and duration of this light.
Good Read Aiming Commands
0: Indicator frequency
1: First indicator duration
after reading
Indicator frequency:
0 to 99 times
Indicator duration:
0 to 99 x 10 ms
Indicator frequency:
0 times
Indicator duration:
100 ms
Example Good Read Aiming Settings:
• To turn on the lights 2 times after 100 ms (default), send this command:
[EF3Q0Q0Q2
• To set the first indicator duration after reading to 500 ms, and then turn on the lights 2
times after 100 ms, send this command:
[EF3Q1Q5Q0
9.4 General Indicator Timing
The buzzer and good read LED share common settings. Specifically, both indicators can be
activated after decoding a barcode and before or after transmitting the data.