EasyManua.ls Logo

Optoma EX556 - Main Procedure

Optoma EX556
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EX556/ES556/EW556/ES555/EX555
Condential
3-2
3-2 Main Procedure
The other troubleshooting procedures please refer to common service manual
3-1(Main Procedure).
No Symptom
Procedure
1 Auto Shut Down
- Check LED Status
a. Power LED ashes amber, Lamp LED light on red
- Check Lamp
- Check Lamp Driver
- Check Main Board
- Check Color Wheel
b.Power LED ashes amber, and Temp LED ashes red
- Check Fan
- Check Main Board
- Check Photo Sensor Board
c. Power LED ashes amber, Temp LED light on red
- Check Main Board
- Check Fan
2
3D Image
Abnormal
- Ensure the using 3D glasses is good and you must face the
projection.
- Ensure the CD in DVD is HQFS format or the graphic card from
PC can support 3D format.
- Ensure your standing distance is less than 6m from screen.
- Ensure the 3D function is on and execute “3D sync invert” in OSD
menu.
- Check main board.

Other manuals for Optoma EX556