How to Install the Server Cover
Orient the cover over the server so the lip edge of the cover is at the front of the server and the
captive retaining screw is at the rear.
Set the cover on top of the server and position it so approximately .5 inch of the cover extends
over the rear of the server.
Use the indent on the top cover to push the cover toward the front of the server until the captive
screw is in position.
To secure the cover, tighten the captive screw.
“How to Install the Server Into the Rack” on page 23
▼
How to Prepare for Operation
Ensure that all new components are installed as described in the component replacement
instructions (see
“Component Replacement Procedures and Topic”on page 29).
Ensure that all existing components are properly seated and connected.
Ensure that all internal cabling is connected and secured within the server and that the cabling
is not obstructing the air ow.
Inspect the interior of the server and remove any tools and loose or foreign debris.
Use a vacuum, compressed air, or an antistatic brush to clean the interior of the server so
component surfaces and server air vents are free of dust.
Caution – Potential for component damage. Do not use liquid or aerosol spray cleaners to clean
the server. Liquid has the potential for causing shorts in electrical systems.
Install the system’s cover. See “How to Install the Server Cover”on page 26.
Install the server in the rack. See
“How to Install the Server Into the Rack”on page 23.
Connect all external cables to the system.
To apply AC power, connect the AC power cords to the server.
When the AC power is applied, the server enters standby mode.
1
2
3
4
Next Steps
1
2
3
4
5
6
7
8
9
Tools and Supplies Needed
Sun Fire X2270 M2 Server Service Manual • January, 2012, –1226