“How to Install the SP Module” on page 60
▼
How to Install the SP Module
See:
■
“Locations of Internal Server Components” on page 30
■
“How to Remove the SP Module” on page 59
Slide the SP module alignment pin over the screw post before installing the SP module.
The SP module alignment pin is designed to help align the SP module with the card connector.
The SP module alignment pin is shipped with the SP module.
Position the SP module so the card’s RJ-45 and HD15 connectors face the rear of the server.
Align connectors on the SP board with the openings in the rear panel of the server chassis.
Use the alignment pin to align the connector on the SP module with the connector on the
motherboard.
Gently push down on the SP module to engage the connector on the module with the connector
on the motherboard.
Tighten the captive screw to secure the SP module.
See Also
BeforeYou Begin
1
2
3
4
5
6
Removing and Installing the SP Module (CRU)
Sun Fire X2270 M2 Server Service Manual • January, 2012, –1260