Grill Temperature
Auger Idle Fuel Feed Rate is too high.
at the 180 Degree Adjust Smoke Control switch (increase the “P” setting) to
Cook Setting is too decrease Idle Fuel Feed Rate.
High
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.
Grill Temperature At the High temperature setting, the auger runs continually
at the High Cook until the grill temperature reaches 450 degrees.
Setting is too Low
Grill lid is open.
Close grill lid. Grill is designed to operate with grill lid
closed.
Insufficient amount of fuel in fire pot.
Clear auger if jammed.
Tighten auger connection to auger motor shaft if slipping.
Replace auger and/or auger motor if defective.
Damp fuel source.
Replace damp fuel with good dry fuel.
Adverse operating conditions.
Shield grill from cold wind and/or rain.
Grill may not be able to attain 450 degrees in an extremely
cold operating environment.
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.