STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version MX60 has a few default settings that di er from the Standard version default
settings. However, there are no di erences in performance and e ciency between the two ver-
sions. The Standard and Australian version can be identi ed as follows:
Standard version Australian version
Below are a few default setting di erences between the Standard and Australian version.
Settings Standard Australian
Charger Amps Absorb Float Amps Absorb Float
12 V 60 14.4 V 13.6 V 60 14.4 V 13.8 V
24 V 60 28.8 V 27.2 V 60 8.8 V 27.6 V
36 V 60 43.2 V 40.8 V 60 43.2 V 41.4 V
48 V 60 57.6 V 54.4 V 60 57.6 V 55.2 V
60 V 60 72.0 V 68.0 V 60 72.0 V 69.0 V
Equalize Equalize Volts Equalize Volts
12 V 14.4 14.7
24 V 28.8 29.4
36 V 43.2 44.1
48 V 57.6 58.8
60 V 72.0 73.5
Equalize Time 01 Hours 03 Hours
OutBack 12V