4. Multimeter Features
Data Hold Mode
(1) Press
to freeze the display during measurement,
will be shown on the
display.
(2) Press again to exit this mode.
Note: This function is not available when measuring diodes and transistor.
Capturing Max. and Min. Values
In MAX mode, the measured maximum value will be held; In MIN mode, the measured
minimum value will be held.
(1) Press
to cycle between the MAX mode and MIN mode.
(2) Press for more than 2 seconds to exit the mode.
In this mode, the manual range mode will be activated automatically. Analog bar graph is
not displayed. Auto power-off function is disabled.
Note: This function is not available when measuring diodes, capacitance, transistor, and
frequency.
Making Relative Measurements
When making relative measurements, reading is the difference between a stored
reference value and the input signal.
(1) Press
to enter the relative mode.
The measurement value when pressing is stored as the reference value.
In this mode, REL△ (current reading) = input value - reference value.
(2) Press it again to exit the mode.
In relative measurement, the manual range mode will be activated automatically. (The
relative measurement should be carried out under a certain range, that is, this function is
only available under the manual range mode.) Analog bar graph is not displayed.
Note: This function is not available when measuring diodes, transistor, and frequency.