6.Technical Specifications
37
Characteristics
Instruction
Display
35 series 6000
B41T(+) 21999
Frequency Response (Hz)
The model
without "T"
(40 - 400) Hz
The model
with "T"
35 series (40 - 1000) Hz
B41T(+) (40 - 10000) Hz
Sample rate for digital data
3 times/second
Sample rate for analog bar
graph
30 times/second
Bluetooth
B35(T)(+)
B41T(+)
D35(T) Without
Auto ranging
True RMS
The model with "T" has this function.
Diodes Test
Measuring Transistor
Sleep Mode
Continuity Test
Low battery indication
(The "
" is displayed when the battery is under
the proper operation range.)
Data Hold
Relative Measurement
MAX/MIN Value
LCD Backlight
Analog bar graph
61 Segments
Input Protection
Input Impedance
10
Battery
3 V (1.5 V × 2) AA alkaline batteries
LCD Size
69 mm * 52 mm
Weight (without package)
0.32 kg
Dimension
85 mm * 185 mm * 30 mm
Working temperature
0 to 40
Storage temperature
10 to 60
Relative Humidity
80%
Altitude
Operating: 3,000 m
Non-operating: 15,000 m
Interval Period of Adjustment:
One year is recommended for the calibration interval period.