Users Manual of OWON Colour Digital Storage Oscilloscope
21
Introduction to the Horizontal System
Shown as Fig.12, there are a button and two knobs in the “HORIZONTAL
CONTROLS”. The following practices will gradually direct you to be familiar with
the setting of horizontal time base.
Fig.12 Horizontal Control Zone
1. Use the horizontal “SEC/DIV” knob to change the horizontal time base setting
and observe the consequent status information change. Rotate the horizontal
SEC/DIV” knob to change the horizontal time base, and it can be found that the
Horizontal Time Base” display in the status bar changes accordingly. The
horizontal scanning speed steps from 5ns up to 100s according to the stepping
mode of
1-2.5-5---- PDS5022S;
125 ---- PDS6042SPDS6062SPDS6062TPDS7062TPDS7102T.
2. Use the “HORIZONTAL POSITION knob to adjust the horizontal position of
the signal in the waveform window. The “HORIZONTAL POSITION knob is
used to control the triggering displacement of the signal or for other special
applications. If it is applied to triggering the displacement, it can be observed that
the wave form moves horizontally with the knob when you rotate the
Horizontal Position” knob.
3. With the “HORIZONTAL MENU” button pushed down, you can set and
initiate the Window Expansion.