EasyManuals Logo

Paccar MX Series User Manual

Paccar MX Series
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
PEC017
5/3/2018 Page 18 of 105
EIST with PTO Mode
N186
Page 15
Min
Default
Max
Idle Time in PTO Mode
1
5
1092
Non-Programmable Parameters
Parameter Name
Number
Min/Max/Default/Units
EIST Low Oil Temperature Overrule
Limit
N195
DEFAULT = 30 °(F)
EIST Low Fuel Temperature Overrule
Limit
N196
DEFAULT = 23 °(F)
Note Regarding Preferred Settings
If the customer accepts the preferred EIST settings within Prospector, they will be
unable to make changes to the following parameters until they exceed the expiration
distance specified on the order:
Timer Setting Non-PTO Mode With Park Brake Set
Timer Setting PTO Mode w/o Park Brake Set
Expiration Distance
Reset EIST Timer Based on Engine Load
Low Ambient Temperature Overrule
High Ambient Temperature Overrule
Overrule EIST Timer Based on Engine Load No Shutdown
ON/OFF Requirements
EIST
ON
OFF
EIST Enabled
EIST Disabled
Vehicle Speed = 0 MPH
Vehicle Speed > 0 MPH
Outside Ambient Air Temperature Override
ON
OFF
Enable Ambient Overrule Temperature =
Yes
Enable Ambient Overrule Temperature =
No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paccar MX Series and is the answer not in the manual?

Paccar MX Series Specifications

General IconGeneral
Engine TypeDiesel
ConfigurationInline 6-cylinder
Displacement12.9 liters
Torque Range1850 lb-ft
Emission StandardGHG17
Bore5.12 inches (130 mm)
AspirationTurbocharged
Fuel SystemCommon Rail