PEC017
5/3/2018 Page 52 of 105
PTO Control
Configuration
In-Cab
Throttle
Pedal
In-Cab
Set &
Resume
Switches
Remote
Throttle
Control
Remote
Set &
Resume
Switches
Mobile Cab Station
Accelerator and
Switches
2092047
1000292
Enabled
Enabled
Disabled
Disabled
Parameter
Number
Parameter Description
Required Value
N078
Disable PTO Mode w/Clutch Depressed
OFF
N079
Require Parking Brake for PTO Mode
OFF
N089
Neutral Required for PTO Mode
OFF
N101
Disable PTO Mode w/ Brake Depressed
ON
N102
Signal Source for Remote Main Switch
0
N110
Engine Speed Capture or Engine Speed Preset w/ Set
Switch
CAPTURE (1)
N306
Enable Engine Speed Control via TSC1
OFF
Table 12.2 Mobile Cab Station Accelerator and Switches Configuration
PTO Control
Configuration
In-Cab
Throttle
Pedal
In-Cab
Set &
Resume
Switches
Remote
Throttle
Control
Remote
Set &
Resume
Switches
Stationary
Cab Station
Switches Only
2092048
1000293
Disabled
Enabled
Disabled
Disabled
Parameter
Number
Parameter Description
Required Value
N079
Require Parking Brake for PTO Mode
ON
N102
Signal Source for Remote Main Switch
0
N306
Enable Engine Speed Control via TSC1
OFF
Table 12.3 Stationary Cab Station Switches Only Configuration