Caution:
Do not overfill the mixing biocontainer!
Do not open the tote doors once the mixing biocontainer is full or partially filled with fluid.
Caution:
Ensure bag inflation valve is set to ‘off’ position prior to opening the powder port.
Operating the Mixer
The mixer speed (revolutions per minute rpm) and direction of rotation are controlled by
the panel on the UCI. The mixer can be rotated in a counter-clockwise direction to provide
‘down-flow’ pumping action to the fluid or in a clockwise direction to provide ‘up-flow’
pumping action on the fluid.
Note: Maximum life (continuous mixing) is 3 days (72 hours).
Figure 29
Setting the impeller speed (rpm) for the mixer
19
USD 2743 www.pall.com/biopharm
STOPRUN
AUTO
FWD
RUN
REV
M
R
F
To set the rpm/speed for the
rotation, use the panel to
increase the rpm figure to the
desired value.