DIS-12 
 
12.  Removal of CAMERA C.B.A. 
1.  Remove the Side Case R S Unit. 
2. Disconnect connector P1004 and P1006 on 
CAMERA C.B.A.. 
3. Unscrew the 4 screws (T) and remove the 
CAMERA C.B.A.. 
NOTE: When removal of the CAMERA C.B.A., the 
connector P1009 is disconnected (P1009 is 
connected between CAMERA and BACK 
CONNECT C.B.A.). Be careful not to 
damage the connector P1009. 
Check the connector has been connected 
securely when the CAMERA C.B.A. is 
installed. 
Moreover, please do not hit the CAMERA 
C.B.A. to the plate in this side when you 
remove or install the CAMERA C.B.A.. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
13.  Removal of Lens Unit 
1.  Remove the CAMERA C.B.A.. 
2.  Unscrew the 4 screws (U) and remove the Lens 
Unit. 
NOTE: When installing a Lens Unit, set the ZOOM 
SW to SERVO position. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.  Removal of Zoom Motor Unit 
1.  Remove the Lens Unit. 
2.  Soldering is removed on the zoom motor. 
3.  Unscrew the 2 screws (V) and remove the Zoom 
Motor Unit. 
NOTE: Match the hole (A) and projection of Lens 
Unit as shown in figure and tighten the 2 
screws (V) in installation of Zoom Motor 
Unit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SILVER 
4mm 
SCREW (T)   
P1004 
SCREW (T) 
P1006 
P1009 
SCREW (T) 
CAMERA 
C.B.A. 
LENS UNIT 
SILVER 
4mm 
SCREW (U)   
SCREW (U) 
Hole (A) 
5mm 
SILVER 
SCREW (V)   
Unsolder 
ZOOM MOTOR UNIT 
SCREW (V)