- 189 -
≥ In the following cases, even when [TIME STAMP] is set to [ON], the date and time of recording
are not displayed:
j When [REC FORMAT] is set to [SA 480/59.94i] or [SA 576/50.00i] (l 165)
j When [2 SLOTS FUNC.] is set to [DUAL CODEC] (l 181)
j When [DATE/TIME] is set to [OFF]
j During Freeze Frame (l 91)
j During Super Slow Recording (l 106)
j In Variable Frame Rate Mode (l 103)
j (If using )
When this unit is connected to the SDI OUT terminal of the external device and the external
output resolution is set to PsF (l 134)
≥ Even when [VIDEO OUT OSD] is set to [OFF], the date and time of recording are displayed on
the external monitor screen. (l 131)
≥ The date and time of recording displayed during [TIME STAMP] recording and the date and time
displayed during the playback of the image may not exactly be the same.
Selects the compensation mode for the time code. (l 80)
≥ Set [SYSTEM FREQ] to [59.94Hz]. (l 164)
Sets the way the time code will move. (l 80)
Initial value of the time code can be set. (l 81)
≥ Set [REC MODE] to [AVCHD]. (l 164)
User Information can be set. (l 81)
You can synchronize the time code of the external device with that of this unit. (l 83)
[DF MODE]
[DF]/[NDF]
[TCG]
[FREE RUN]/[REC RUN]
[TC PRESET]
[UB PRESET]
( only)
[EXT TC LINK]
[MASTER]/[SLAVE]
AG-UX180