- 83 -
Synchronizing the time code with an external
device [AG-UX180]
You can synchronize the default time code during multi-camera recording.
≥ In the following section, the device with the reference time code is referred to as “master”, while
the device to be synchronized is referred to as “slave”.
1 Connect the TC PRESET IN/OUT terminals of
the two devices with a BNC cable
(commercially-available), and turn them on.
≥ Apply the same [
REC FORMAT
] and [
DF MODE
] settings
to the two devices. (l 80, 165)
2 (On the master device)
Select the [
TCG] menu.
3 (On the master device)
Select the [EXT TC LINK] menu.
≥ The time code will be output from the TC PRESET IN/OUT terminal.
≥ To cancel the output of the time code, touch [EXIT].
4 (On the slave device)
Select the [EXT TC LINK] menu.
≥ [TCG] will be set to [FREE RUN].
5 (On the slave device)
Press the RESET/TC SET button.
≥ “TC LINK OK” will be displayed and the time code will be synchronized with that of the master
device.
≥ When the time code is not synchronized correctly, “TC LINK NG” is displayed.
≥ To cancel the operation without synchronizing the time code, touch [EXIT].
≥ Use a commercially-available, double-shielded BNC cable equivalent to 5C-FB.
≥ [EXT TC LINK] cannot be set to [SLAVE] in the following cases:
j During Super Slow Recording (l 106)
j In Variable Frame Rate Mode (l 103)
j During the Interval Recording (l 186)
A TC PRESET IN/OUT terminal
: [RECORD SETUP] # [TCG] # [FREE RUN]
: [RECORD SETUP] # [EXT TC LINK] # [MASTER]
: [RECORD SETUP] # [EXT TC LINK] # [SLAVE]
TC PRESET
IN/OUT
AG-UX180ED(DVQP1171ZA)_E.book 83 ページ 2016年11月28日 月曜日 午前11時32分