- 218 -
The card is nearly
full
Status indicator s
On-screen display
The remaining recordable time flashes
red. (When it is less than 1 minute)
AG ROP application screen
[ ] flashes once per second.
(When it is less than 1 minute)
Meaning of the warning The SD card is almost out of space.
Recording/playback The recording continues.
Solution
Delete unnecessary scenes or use a
new SD card as needed.
The cooling fan has
stopped
Status indicator It flashes twice per second.
On-screen display s
AG ROP application screen
[ ] flashes four times per
second.
Meaning of the warning
A cooling fan error has stopped the
cooling fan.
Recording/playback
The operation stops and this unit turns
off automatically.
Solution
Check to see if the air inlet or outlet is
blocked. If the warning persists, consult
your dealer.
WARNING
WARNING
AG-UX180ED(DVQP1171ZA)_E.book 218 ページ 2016年11月28日 月曜日 午前11時32分