2. Norrowing
Vertical Airflow Direction
– During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
– During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to
10°, 13°, 16°, 19°, 22° under Cooling and Soft Dry operation mode.
12.5. Indoor Fan Speed Control
• Indoor Fan Speed can be set using remote control.
12.5.1. Fan Speed Rotation Chart
12.5.2. Automatic Fan Speed Control
• When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
- Fan speed rotates in the range of Hi, Me and Lo-.
- Deodorizing Control will be activated.
COOL/DRY CS-PC24GKF CS-PC18GKF
Hi 1640 1450
Me 1460 1330
Lo+ 1400 1280
Lo 1310 1150
Lo- 1100 980
SLo 860 780