55
9 Close grille door by tighten with screw and close the front panel.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
10.2.4.1 Wire Stripping, Connecting Requirement
Recommended
length (mm)
a b cdef g
55 35 35 50 40 35 60
Recommended
length (mm)
Tape
Connection cable
Tape
Power supply cord
Ter mi na l Bo a rd
Control
Board
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Holder
Indoor & outdoor
connection cable
Isolating Devices Outdoor unit
Power supply
cord
WARNING
This equipment must
be properly earthed.
Conductor
over inserted
Wire stripping
No loose strand
when inserted
10 ± 1 mm
Conductor
fully inserted
Conductor not
fully inserted
5mmormore
Indoor/outdoor
connection terminal
board
(gap between wires)
WARNING
RISK OF FIRE
JOINING OF WIRES MAY
CAUSE OVERHEATING
AND FIRE.
Do not joint wires
OR
OR
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national wiring rules.
ACCEPT PROHIBITED PROHIBITED