13.14 Odor Cut Control
To reduce the odor released from the unit.
o Start condition
AUTO FAN Speed is selected during COOL or DRY operation.
During freeze prevention control and timer preliminary operation, this control is not applicable.
o Control content
Depends on compressor conditions:
1. Compressor OFF Compressor ON.
The indoor unit fan stops temporarily and then starts to blow at minimum airflow for 50 seconds.
2. Compressor ON Compressor OFF.
The indoor unit fan stops for 90 seconds and then blows at minimum airflow for 20 seconds.