91
14.2 Remote Control Button
14.2.1 SET Button
To check remote control transmission code and store the transmission code to EEPROM.
o Press “Set” button by using pointer.
o Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code change.
o LCD returns to original display if remote control does not operate for 30 seconds.
To limit set temperature range for iAUTO-X, COOL & DRY mode.
o Press “Set” button by using pointer.
o Press TEMP increment or decrement button to choose No. 3.
o Press Timer increment or decrement button to select desired temperature low limit of set temperature for
iAUTO-X, COOL & DRY mode.
o Press Timer Set button to confirm low limit selection.
o Press TEMP increment or decrement button to choose No. 4.
o Press Timer decrement or increment button to select desired temperature high limit of set temperature for
iAUTO-X, COOL & DRY mode.
o Press Timer Set button to confirm high limit selection.
o LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel
button.
14.2.2 RESET (RC)
To clear and restore the remote control setting to factory default.
o Press once to clear the memory.
14.2.3 RESET (AC)
To restore the unit’s setting to factory default.
o Press once to restore the unit’s setting.
14.2.4 TIMER
To change indoor unit indicators’ intensity:
o Press continuously for 5 seconds.
14.2.5 TIMER
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F).
o Press continuously for 10 seconds.
14.2.6 TEMP
To change remote control set temperature range from (16.0°C ~ 30.0°C) (60°F ~ 86°F) to (20.0°C ~ 30.0°C)
(68°F ~ 86°F).
o Press continuously for 15 seconds.