24
8.2 Outdoor Unit
8.2.1 CU-VU9SKQ CU-VU12SKQ
REMARKS
BLACK: (BLK) BLUE: (BLU) WHITE: (WHT) RED: (RED) YELLOW: (YLW) GRAY: (GRY) GREEN: (GRN) BROWN: (BRW)
TERMINAL
BOARD
TO INDOOR UNIT
COMPRESSOR
FAN MOTOR
OUTDOOR AIR TEMP.
SENSOR (THERMISTOR)
PIPING TEMP.
SENSOR (THERMISTOR)
1
2
3
4
CN-TH
(WHT)
AC-WHT
(WHT)
FG1
(GRN)
FG2
(GRN)
GRN
BLK
BLK
WHT
WHT
GRN
AC-BLK
(BLK)
DATA
(RED)
RED
GRY
RAT2
(GRY)
GRY
RAT1
(GRY)
REACTOR
RED
BLU
YLW
U (RED)
FUSE103
T3.15A L250V
FUSE104
(15A 250V)
V (BLU)
W (YLW)
U
V
W
COMP. TEMPERATURE
SENSOR (THERMISTOR)
1
3
CN-TANK
(WHT)
MS
3 ~
P
N
SWITCHING POWER
SUPPLY CIRCUIT
FUSE102
T3.15A L250V
BLU
RED
YLW
FM1 (BLU)
FM2 (RED)
FM3 (YLW)
M
1~
FAN MOTOR
CIRCUIT
FUSE101
(20A 250V)
3
(RED)
2
(WHITE)
1
(BLACK)
N
L
PFC
CIRCUIT
ELECTRONIC CONTROLLER
YLW/GRN
GROUNDING
TERMINAL
SINGLE PHASE
POWER SUPPLY
NOISE FILTER
CIRCUIT
COMMUNICATION
CIRCUIT
RECTIFICATION
CIRCUIT
RECTIFICATION
CIRCUIT
YELLOW
(YLW) OR (C)
BLUE
(BLU)
OR (R)
RED
(RED)
OR (S)
TRADEMARK
COMP. TERMINAL
Resistance of Outdoor Fan Motor Windings
Resistance of Compressor Windings
MODEL CU-VU9SKQ / CU-VU12SKQ MODEL CU-VU9SKQ / CU-VU12SKQ
CONNECTION ACXA95-00130 CONNECTION 9RS092XBA21
BLUE-YELLOW 178.6 Ω U-V 1.152 Ω
BLUE-RED 147.9 Ω U-W 1.152 Ω
V-W 1.152 Ω
Note: Resistance at 20°C of ambient temperature.
Note: Resistance at 20°C of ambient temperature.

Table of Contents

Other manuals for Panasonic CS-VU18SKQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-VU18SKQ and is the answer not in the manual?

Panasonic CS-VU18SKQ Specifications

General IconGeneral
BrandPanasonic
ModelCS-VU18SKQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals