EasyManua.ls Logo

Panasonic CS-VU18SKQ - Random Auto Restart Control; Indication Panel; Nanoe-G Operation

Panasonic CS-VU18SKQ
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
13.8 Random Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes. There are 10 patterns to be selected randomly after power supply resumes.
This control is not applicable during OFF/ON Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
Enable or disable selection
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWE R
DIRECT
AM
PM
AM
ON
OFF
PM
Transmit
“Enable or Disable” code
Normal display mode
Control
Disable
Control
Enable
Press SW to enter customer zone &
Press SW’s to choose function 10
SET
13.9 Indication Panel
LED POWER TIMER nanoe-G DUST SENSOR
Color White White White White / Red
Light ON Operation ON Timer Setting ON
nanoe-G
Mode ON
DUST SENSOR
Mode ON
Light OFF Operation OFF Timer Setting OFF
nanoe-G
Mode OFF
DUST SENSOR
Mode OFF
Note:
If POWER LED blinks, the possible operation of the unit is ON timer sampling.
If TIMER LED blinks, there is an abnormal operation occurs.
13.10 nanoe-G Operation
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
nanoe-G operation start condition
o During unit running at any operation mode, if nanoe-G operation is activated, combination operation
(operation mode + nanoe-G operation) starts.
o During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
nanoe-G operation stop condition
o When OFF/ON button is pressed to stop the operation.
o When nanoe-G button is pressed.
o When OFF Timer activates.
nanoe-G operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
indoor fan restarts.
o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature < 40°C
continuously for 30 minutes.

Table of Contents