6.7. Display of Malfunction Analysis-4 [C8]
Category of abnormal stalling is shown.
1. Proceed the procedures of 6.1. Preparation of Secret Mode.
2. Push the buttons of and till C8 appears, and push the OK button.
Any number of the list is shown.
Sensor does not detect anything. Whole lead disconnection, connectors come off, sensor faulty.
Sensor detects abnormal changes. Partial lead disconnection, sensor faulty.
When Massage mechanism block starts, Sensors are faulty. Each Motor rotation sensor is faulty.
* If Position sensors are faulty, Sensors do not detect any changes.
Operation mode Display Error
Abnormal sensors 0 Normal
1 Up/down sensor does not detect changes
3 Up/down motor rotation sensor
4 Width sensor does not detect changes
6 Massaging motor rotation sensor
10 Tapping motor rotation
11 Ottoman sensor does not detect changes
12 Ottoman sensor detects abnormal changes
13 Reclining sensor does not detect changes
14 Reclining sensor detects abnormal changes
15 Heater sensor error