17
6.8. Display of Malfunction Analysis-5 [C9]
Conditions when abnormality occurred or faulty history are shown.
1. Proceed the procedures of 6.1. Preparation of Secret Mode.
2. Push the buttons of and till C9 appears, and push the OK button.
3. Again, push the OK button, then ''01'' is shown on the display.
Push the buttons of and till 01-03 appears that you need, and push the OK button.
* Display shows the conditions when the Massage mechanism block stopped abnormally. Contents of the display
are connected to ''C4''.
Error information except for the total usage time and each operation time is deleted on No.03.
If these errors occur, the information is memorized as above.
No. Operation mode
01 Display of conditions right before the abnormal stop
02 Display of accumulative abnormal stops
03 Deletion of the accumulative abnormal stop information
No. of times
of errors
Faulty parts Memory contents
1st Up/down sensor Memorize
2nd Width sensor Memorize as the sensor group
3rd Massaging sensor Memorize as the sensor group
4th Tapping motor Memorize
5th Up/down motor Memorize as the sensor group
6th Sub PCB Memorize