3.2 BKEXT (16-bit Data Sign-extended Block Move)
3.2 BKEXT (16-bit Data Sign-extended Block Move)
Instruction format
BKEXT.US DT2 DT3
S2 D
R0
DT0
S1i
Operation unit (●: Available)
List of operands
The starting address of the device storing the data that sign extension is performed.
The ending address of the device storing the data that sign extension is performed.
Destination starting device address
Available devices (●: Available)
*1:Only 16-bit deivces, 32-bit devices, and integer constants can be modified. (Real number constants and character
constants cannot be specified.)
Outline of operation
Performs sign extension for device values in the area specified by [S1] to [S2], and transfers
them to the device address specified by [D] and subsequent addresses.