ex.)
Items (*2) Address Default Data New Data Remarks
C-ID (FSK) sensitivity 04 3D 00 01 (6dB up) 02 (12dB up) When hex changes from “00” to “01” or “02”, gain
increases by 6dB or 12dB.
C-ID (DTMF) sensitivity 04 4B 50 60 (6dB up) 70 (12dB up) When hex changes from “50” to “60” or “70”, gain
increases by 6dB or 12dB.
Frequency 00 01 75 - - UsetheseitemsinaREAD-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
ID 00 10~00 14 Given value - -
Bell length 01 F6 64 (10sec) (*1) 1E (3sec) 14 (2sec) This is time until bell stops ringing.
(Unit: 100ms)
PULSE Dial speed
(10PPS -> 20PPS)
03 48 28 (40msec) (*1) 14 (20msec) - This is pulse make time. (Unit:1ms)
03 49 3C (60msec) (*1) 1E (30msec) - This is pulse break time. (Unit:1ms)
01 E4 57 (870msec) (*1) 2C (440msec) - This is inter-digit time in pulse mode. (Unit:10ms)
(*1)
Bell length 64(hex) = 100(dec) → 100 × 100msec = 10000msec (10sec)
PULSE Dial speed
(10PPS -> 20PPS)
28(hex) = 40(dec) → 40 × 1msec = 40msec
3C(hex) = 60(dec) → 60 × 1msec = 60msec
57(hex) = 87(dec) → 87 × 10msec = 870msec
(*2)
Items Description
C-ID (FSK) sensitivity FSKGain_shiftgain
C-ID (DTMF) sensitivity Foutgains:HPFilter Foutgains
Frequency Setting value of FREQ_TRIM_REG
ID ID
Bell length Time until it stops bell.
PULSE Dial speed
(10PPS -> 20PPS)
Pulse MakeTime and BreakTime.
bMakeTime:Pulse MakeTime Unit: 1ms
bBreakTime:Pulse Break Time Unit: 1ms
Inter-digit time in Pulse mode.
Unit:10ms
62