90
⿎
Counter condition : CNT
Sets the counter conditions.
• Setting / Readout data of counter condition
STX CNT
Sub
command
[Counter No.] [Current value] [Initial value] [End value]
[Step] [Count source] [Flag reset]
27-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of counter condition
STX CNT R
[Counter No.]
1-byte
(Check
sum)
Delimiter
Name Data length [byte] Description Remarks
Counter No. 1 “0”–“7” “4”–“7”: common counter
Current value 6 “000000”–“999999”
No minus number.
Initial value 6 “000000”–“999999”
End value 6 “000000”–“999999”
Step 6 “000000”–“999999”
Count source 1
“0”: Counter 0
“1”: Counter 1
“2”: Counter 2
“3”: Counter 3
“4”: Counter 4
“5”: Counter 5
“6”: Counter 6
“7”: Counter 7
“8”: Trigger input
Flag reset 1
“0”: reset OFF at re-dating
“1”: reset ON at re-dating
When the marking on the ying object is
valid, set “0”.
Reference
• When marking on the ying object is valid, counter reset at re-dating timing cannot be used.
ME-LP400V-EX-6